Sean Condon | fae8e66 | 2016-12-15 10:25:13 +0000 | [diff] [blame] | 1 | module ietf-system-microsemi { |
| 2 | |
| 3 | namespace "http://www.microsemi.com/microsemi-edge-assure/msea-system"; |
| 4 | prefix "sys-ms"; |
| 5 | |
| 6 | import ietf-yang-types { |
| 7 | prefix yang; |
| 8 | revision-date 2013-07-15; |
| 9 | } |
| 10 | |
| 11 | import ietf-inet-types { |
| 12 | prefix inet; |
| 13 | revision-date 2013-07-15; |
| 14 | } |
| 15 | |
| 16 | import msea-types { |
| 17 | prefix msea; |
| 18 | revision-date 2016-02-29; |
| 19 | } |
| 20 | |
| 21 | import ietf-system { |
| 22 | prefix sys; |
| 23 | revision-date 2014-08-06; |
| 24 | } |
| 25 | |
Sean Condon | 1dbcd71 | 2017-10-19 12:09:21 +0100 | [diff] [blame] | 26 | // import ietf-netconf-acm { |
| 27 | // prefix nacm; |
| 28 | // revision-date 2012-02-22; |
| 29 | // } |
Sean Condon | fae8e66 | 2016-12-15 10:25:13 +0000 | [diff] [blame] | 30 | |
| 31 | /*** META INFORMATION ***/ |
| 32 | |
| 33 | organization |
| 34 | "Microsemi Inc., FTD Division"; |
| 35 | |
| 36 | contact |
| 37 | "Web URL: http://www.microsemi.com/ |
| 38 | E-mail: info@microsemi.com |
| 39 | Postal: Microsemi Corporation Corporate Headquarters |
| 40 | One Enterprise Aliso Viejo, |
| 41 | CA 92656 |
| 42 | U.S.A. |
| 43 | Phone: +1 949 380 6100 |
| 44 | Fax: +1 949 215-4996"; |
| 45 | |
| 46 | description |
| 47 | "This YANG module extends the IETF System objects with some extra configuration attributes |
| 48 | |
| 49 | Copyright 2015 Microsemi Inc. |
| 50 | All rights reserved."; |
| 51 | |
| 52 | reference "RFC 7317: A YANG Data Model for System Management"; |
| 53 | |
| 54 | revision "2016-05-05" { |
| 55 | description |
| 56 | "Updated for ZTP support - Sean Condon, Microsemi"; |
| 57 | } |
| 58 | |
| 59 | revision "2015-10-01" { |
| 60 | description |
| 61 | "Initial version to augment IETF-SYSTEM YANG module - Sean Condon, Microsemi"; |
| 62 | } |
| 63 | |
| 64 | typedef identifier { |
| 65 | type string { |
| 66 | length "1..255"; |
| 67 | pattern "[a-zA-Z0-9\-._]*"; |
| 68 | } |
| 69 | description |
| 70 | "A simple string with only alphabetic or numeric and dash, dot and underscore"; |
| 71 | } |
| 72 | |
| 73 | grouping upgrade-file-attributes { |
| 74 | leaf file-name { |
| 75 | type string; |
| 76 | description "The name of the update TAR file as found on the device"; |
| 77 | } |
| 78 | |
| 79 | leaf file-date { |
| 80 | type yang:date-and-time; |
| 81 | description "The date of the update TAR file as found on the device"; |
| 82 | } |
| 83 | |
| 84 | leaf file-size { |
| 85 | type uint32; |
| 86 | description "The size of the update TAR file as found on the device"; |
| 87 | } |
| 88 | } |
| 89 | |
| 90 | |
| 91 | grouping upgrade-attributes { |
| 92 | description "Attributes from the /update.tar file"; |
| 93 | |
| 94 | leaf version { |
| 95 | type uint32; |
| 96 | description "The version of this portion of the /update.tar"; |
| 97 | } |
| 98 | |
| 99 | leaf crc32 { |
| 100 | type uint32; |
| 101 | description "The CRC32 value of this portion of the /update.tar"; |
| 102 | } |
| 103 | |
| 104 | leaf length { |
| 105 | type uint32; |
| 106 | description "The length of this portion of the /update.tar"; |
| 107 | } |
| 108 | } |
| 109 | |
| 110 | grouping ddm-attributes { |
| 111 | |
| 112 | leaf high-alarm-thresh { |
| 113 | description "The high alarm threshold value"; |
| 114 | type decimal64 { |
| 115 | fraction-digits 6; |
| 116 | } |
| 117 | } |
| 118 | |
| 119 | leaf high-warn-thresh { |
| 120 | description "The high warn threshold value"; |
| 121 | type decimal64 { |
| 122 | fraction-digits 6; |
| 123 | } |
| 124 | } |
| 125 | |
| 126 | leaf low-warn-thresh { |
| 127 | description "The low warn threshold value"; |
| 128 | type decimal64 { |
| 129 | fraction-digits 6; |
| 130 | } |
| 131 | } |
| 132 | |
| 133 | leaf low-alarm-thresh { |
| 134 | description "The low alarm threshold value"; |
| 135 | type decimal64 { |
| 136 | fraction-digits 6; |
| 137 | } |
| 138 | } |
| 139 | } |
| 140 | |
| 141 | feature serial-number { |
| 142 | description "Set of readonly attributes that identify the hardware"; |
| 143 | } |
| 144 | |
| 145 | feature remote-upgrade { |
| 146 | description |
| 147 | "Indicates that the device supports upgrade of fabric, linux and fabric header. |
| 148 | This expects a file /update.tar on the device - |
| 149 | put there through SFTP or some other file transfer method"; |
| 150 | } |
| 151 | |
| 152 | |
| 153 | augment "/sys:system" { |
| 154 | description |
| 155 | "Extends the SYSTEM with some extra configuration attributes required for setup."; |
| 156 | |
| 157 | leaf asset-tag { //Microsemi specific configuration attribute |
| 158 | type identifier; |
| 159 | description |
| 160 | "An asset tag field for the device."; |
| 161 | } |
| 162 | |
| 163 | leaf description { //Microsemi specific configuration attribute |
| 164 | type string { |
| 165 | length "0..256"; |
| 166 | pattern "[a-zA-Z0-9\\-_. ,]*"; |
| 167 | } |
| 168 | description "A description for the device."; |
| 169 | } |
| 170 | |
| 171 | leaf longitude { //Microsemi specific configuration attribute |
| 172 | type decimal64 { |
| 173 | fraction-digits 7; |
| 174 | range "-180..180"; |
| 175 | } |
| 176 | description |
| 177 | "Longitude for the device expressed in decimal degrees. |
| 178 | Positive values represent East and negative values represent West"; |
| 179 | } |
| 180 | |
| 181 | leaf latitude { //Microsemi specific configuration attribute |
| 182 | type decimal64 { |
| 183 | fraction-digits 7; |
| 184 | range "-90..90"; |
| 185 | } |
| 186 | description |
| 187 | "Latitude for the device expressed in decimal degrees |
| 188 | Positive values represent North and negative values represent South"; |
| 189 | } |
| 190 | } |
| 191 | |
| 192 | |
| 193 | augment "/sys:system-state" { |
| 194 | description |
| 195 | "Extends the SYSTEM-STATE with some extra configuration attributes required for setup. |
| 196 | |
| 197 | All attributes are automatically config=false because they extend system-state"; |
| 198 | |
| 199 | container remote-upgrade { |
| 200 | description "Details of the /update.tar file present on the system. |
| 201 | These are all read-only because they are under system-state"; |
| 202 | |
| 203 | choice file-present-choice { |
| 204 | case not-present { |
| 205 | leaf file-not-found { |
| 206 | type string; |
| 207 | description "Gives the name of the expected file. Usually /update.tar"; |
| 208 | } |
| 209 | } |
| 210 | |
| 211 | case file-present { |
| 212 | uses upgrade-file-attributes; |
| 213 | |
| 214 | leaf file-validity { |
| 215 | type string; |
| 216 | description "Gives an indication if the file is valid, or if not, the reason why"; |
| 217 | } |
| 218 | |
| 219 | container fabric-image { |
| 220 | uses upgrade-attributes; |
| 221 | } |
| 222 | |
| 223 | container linux-image { |
| 224 | uses upgrade-attributes; |
| 225 | } |
| 226 | } |
| 227 | } |
| 228 | } |
| 229 | |
| 230 | leaf hostname { |
| 231 | type string; |
| 232 | description "The hostname of the system. When DHCP or ZTP |
| 233 | is active the hostname will not be configured through NETCONF"; |
| 234 | } |
| 235 | |
| 236 | container ntp { |
| 237 | if-feature sys:ntp; |
| 238 | description "The list of NTP servers active on the system. When DHCP or ZTP |
| 239 | is active the NTP servers will not be configured through NETCONF"; |
| 240 | |
| 241 | leaf-list server { |
| 242 | type string; |
| 243 | description "An NTP server active on the system"; |
| 244 | } |
| 245 | } |
| 246 | |
| 247 | container dns-resolver { |
| 248 | description "The list of DNS servers active on the system. When DHCP or ZTP |
| 249 | is active the DNS servers will not be configured through NETCONF"; |
| 250 | |
| 251 | leaf-list server { |
| 252 | type string; |
| 253 | description "A DNS server active on the system"; |
| 254 | } |
| 255 | |
| 256 | leaf-list search { |
| 257 | type string; |
| 258 | description "A DNS search domain active on the system"; |
| 259 | } |
| 260 | |
| 261 | } |
| 262 | |
| 263 | container diagnostic-monitoring { |
| 264 | |
| 265 | container temperature { |
| 266 | description "The temperature and thresholds of the device"; |
| 267 | |
| 268 | leaf measured { |
| 269 | description "The measured transceiver temperature at the current time"; |
| 270 | type decimal64 { |
| 271 | fraction-digits 6; |
| 272 | } |
| 273 | units "°C"; |
| 274 | reference |
| 275 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 276 | Transceivers Rev 12.1 September 12, 2014 Section 9.1"; |
| 277 | } |
| 278 | |
| 279 | uses ddm-attributes; |
| 280 | } |
| 281 | |
| 282 | container voltage { |
| 283 | description "The core voltage and thresholds of the device"; |
| 284 | |
| 285 | leaf measured { |
| 286 | description "The measured voltage at the current time"; |
| 287 | type decimal64 { |
| 288 | fraction-digits 6; |
| 289 | } |
| 290 | units "V"; |
| 291 | reference |
| 292 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 293 | Transceivers Rev 12.1 September 12, 2014 Section 9.1"; |
| 294 | } |
| 295 | |
| 296 | uses ddm-attributes; |
| 297 | } |
| 298 | |
| 299 | container tx-bias { |
| 300 | description "The transmit (Tx) bias and thresholds of the device"; |
| 301 | |
| 302 | leaf measured { |
| 303 | description "The measured transmit (Tx) bias at the current time"; |
| 304 | type decimal64 { |
| 305 | fraction-digits 6; |
| 306 | } |
| 307 | units "mA"; |
| 308 | reference |
| 309 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 310 | Transceivers Rev 12.1 September 12, 2014 Section 9.1"; |
| 311 | } |
| 312 | |
| 313 | uses ddm-attributes; |
| 314 | } |
| 315 | |
| 316 | container tx-power { |
| 317 | description "The transmit (Tx) power and thresholds of the device"; |
| 318 | |
| 319 | leaf measured { |
| 320 | description "The measured transmit (Tx) power at the current time"; |
| 321 | type decimal64 { |
| 322 | fraction-digits 6; |
| 323 | } |
| 324 | units "mV"; |
| 325 | reference |
| 326 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 327 | Transceivers Rev 12.1 September 12, 2014 Section 9.1"; |
| 328 | } |
| 329 | |
| 330 | uses ddm-attributes; |
| 331 | } |
| 332 | |
| 333 | container rx-power { |
| 334 | description "The receive (Rx) power and thresholds of the device"; |
| 335 | |
| 336 | leaf measured { |
| 337 | description "The measured receive (Rx) power at the current time"; |
| 338 | type decimal64 { |
| 339 | fraction-digits 6; |
| 340 | } |
| 341 | units "mV"; |
| 342 | reference |
| 343 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 344 | Transceivers Rev 12.1 September 12, 2014 Section 9.1"; |
| 345 | } |
| 346 | |
| 347 | uses ddm-attributes; |
| 348 | } |
| 349 | } |
| 350 | } |
| 351 | |
| 352 | augment "/sys:system-state/sys:platform" { |
| 353 | description |
Sean Condon | 1dbcd71 | 2017-10-19 12:09:21 +0100 | [diff] [blame] | 354 | "Extends the SYSTEM-STATE platform with some extra configuration attributes required for setup. |
Sean Condon | fae8e66 | 2016-12-15 10:25:13 +0000 | [diff] [blame] | 355 | |
| 356 | All attributes are automatically config=false because they extend system-state"; |
| 357 | |
| 358 | container device-identification { |
| 359 | if-feature serial-number; |
| 360 | config false; |
| 361 | |
| 362 | leaf vendor-name { |
| 363 | type string; |
| 364 | description |
| 365 | "Device Vendor Name"; |
| 366 | reference |
| 367 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 368 | Transceivers Rev 12.1 September 12, 2014 Table 4-1 Address A0H Bytes 20-35"; |
| 369 | } |
| 370 | |
| 371 | leaf vendor-part-number { |
| 372 | type string; |
| 373 | description |
| 374 | "Device Vendor Part Number"; |
| 375 | reference |
| 376 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 377 | Transceivers Rev 12.1 September 12, 2014 Table 4-1 Address A0H Bytes 40-55"; |
| 378 | } |
| 379 | |
| 380 | leaf vendor-revision { |
| 381 | type string; |
| 382 | description |
| 383 | "Device Vendor Revision"; |
| 384 | reference |
| 385 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 386 | Transceivers Rev 12.1 September 12, 2014 Table 4-1 Address A0H Bytes 56-59"; |
| 387 | } |
| 388 | |
| 389 | leaf serial-number { |
| 390 | type string; |
| 391 | description |
| 392 | "Device Serial Number"; |
| 393 | reference |
| 394 | "SFF-8472 Specification for Diagnostic Monitoring Interface for Optical |
| 395 | Transceivers Rev 12.1 September 12, 2014 Table 4-1 Address A0H Bytes 68-83"; |
| 396 | } |
| 397 | |
| 398 | container processor { |
| 399 | description "Details of the processor hardware in the device"; |
| 400 | |
| 401 | leaf serialnumber { |
| 402 | type yang:hex-string; |
| 403 | description "The serial number of the processor"; |
| 404 | } |
| 405 | |
| 406 | leaf x509-device-certificate-pem { |
| 407 | type string; |
| 408 | description "X509 Device certificate in PEM (Base 64 format)"; |
| 409 | } |
| 410 | } |
| 411 | } |
| 412 | } |
Sean Condon | fae8e66 | 2016-12-15 10:25:13 +0000 | [diff] [blame] | 413 | } |