| ** April 4, 2013 ** |
| - denser iperf display |
| - don't pop alert on command error response. just log it |
| |
| ** April 4, 2013 ** |
| iperf display implemented |
| - scaled to 50,000,000 |
| - update rate is every 2s |
| - the display does not draw until receiving 2 buffers of data (this way if there is a stale buffer it doesn't get displayed) |
| - duration is 10000 seconds. seems like there is no need for a button to restart? |
| - displaying 10s data |
| - if the data underruns (either because the server response is too slow or because the iperf data stops being updated) the display draws 0s |
| - seeing the data stall a lot (timestamp and end-time remain the same through many fetches) |
| |
| ** April 4, 2013 ** |
| Fix issues: |
| 305 - "close x" now unselects flow. double click to delete a flow |
| 323 - gui now recovers on timeout errors and polls again |
| 324 - fixed problem with added flows not displaying |
| 325 - fixed logic displaying flows in topology view |
| |
| ** March 28, 2013 ** |
| - add and delete flow implemented |
| - to add flow |
| - mouse down in src edge switch |
| - drag to dst edge switch |
| - release/confirm to create flow |
| - to delete flow |
| - select flow in flow chooser |
| - click "close" button in flow table |
| - confirm |
| - same "pending" style as other actions |
| |
| ** March 28, 2013 ** |
| - basic flow chooser |
| - click in "eye" to show full list |
| - click on "eye" in full list to monitor that flow in the top slot (and show the flow in topology) |
| - other flows get pushed down one slot |
| - when a flow is pushed off the list, it is no longer displayed in topology |
| - bug fix for link disappearing after being added |
| - color improvements |
| - draw vector while linking to make it clearer what's going to happen |
| |
| ** March 27, 2013 ** |
| - click onos node "eye" icon to highlight switches associated with that controller |
| - double click onos node else where to activate/deactivate |
| - double click core switch to activate/deactivate |
| - mouse down on switch, drag to other switch, mouse up to make link up/down |
| allowed links are |
| aggregation->core (link up/down) |
| core->core (link up/down) |
| - pending states for links, switches and controllers after executing command |
| object pulses until state change or timeout (12s) |
| - merge from upstream/master |
| |
| ** March 25, 2013 ** |
| - First pass at flow chooser |
| - Uses mock data |
| - Select flow to show the flow in topology view |
| - Selected flow currently always shows "marching ants" Once iperf is setup the movement will only be when there is iperf traffic |
| - Still need to do popup flow chooser to "monitor" flows in the flow panel |
| |
| ** March 23, 2013 ** |
| - Link and switch state updates dynamically |
| - Link direction is indicated with arrow heads |
| |
| ** March 22, 2013 ** |
| - Workarounds for Chrome v25 rendering bugs |
| - Fixed broken proxy functionality in restapi2.py |
| - webui should now work when hosted from a different server than the controller (where it uses gui3.onlab.us:8080) and also when run from the same server (where it uses localhost:8080) |
| |
| ** March 20, 2013 ** |
| - URL parameters control functions as follows: |
| http://localhost:9000/ons-demo/index.html |
| uses the ONOS_HOST defined in restapi2.py. currently http://gui3.onlab.us:8080 |
| http://localhost:9000/ons-demo/index.html?proxy |
| uses the index.html host to proxy to ONOS_HOST (works around cross site scripting restrictions to allow the WebUI to be served from a different server than the one that hosts the controller) |
| http://localhost:9000/ons-demo/index.html?mock |
| uses the mock JSON responses under ons-dmo/data |
| - clicking a controller behavior change |
| 1) if all controllers are selected, deselects all controllers except the one clicked |
| 2) if only the clicked controller is selected, selects all controllers again |
| - Update configuration files to match test bed |
| - Update sample JSON files from test bed |
| |
| ** March 19, 2013 ** |
| - aggregation switch sample data DPIDs do not match official switch config. |
| - switch config hacked 00:00:00:00:00:00:01:01 ==> 00:00:00:00:00:00:01:00 etc. |
| - layout does not dynamically adjust when window is resized |
| - refresh browser window after resizing to fix layout |