module openconfig-transport-line-protection {
yang-version "1";
// namespace
namespace "http://openconfig.net/yang/optical-transport-line-protection";
prefix "oc-line-protect";
import openconfig-extensions { prefix oc-ext; }
import openconfig-types { prefix oc-types; }
import openconfig-platform { prefix oc-platform; }
// meta
organization "OpenConfig working group";
contact
"OpenConfig working group
www.openconfig.net";
description
"This model describes configuration and operational state data
for optical line protection elements, deployed as part of a
transport line system. An Automatic Protection Switch (APS)
is typically installed in the same device as the amplifiers
and wave-router, however an APS can also be a standalone
device. In both scenarios, it serves the same purpose of
providing protection using two dark fiber pairs to ensure the
amplifiers can still receive a signal if one of the two fiber
pairs is broken.";
//
// Automatic Protection Switch (APS) port details and directionality.
// _________
// | |
// | | <=== LINE-PRIMARY-IN
// | |
// COMMON-IN ===> | | ===> LINE-PRIMARY-OUT
// | |
// | APS |
// COMMON-OUT <=== | |
// | | <=== LINE-SECONDARY-IN
// | |
// | | ===> LINE-SECONDARY-OUT
// |_______|
//
oc-ext:openconfig-version "0.3.1";
revision "2017-09-08" {
description
"Correct bug with OSC interfaces";
reference "0.3.1";
}
revision "2017-07-08" {
description
"Support multiple OCMs, add monitor port type
and refs to hw ports, ";
reference "0.3.0";
}
revision "2017-03-28" {
description
"Added min/max/avg stats, status for media channels, OCM, APS";
reference "0.2.0";
}
revision "2016-08-05" {
description
"Initial public release";
reference "0.1.0";
}
// extension statements
// feature statements
// identity statements
identity APS_PATHS {
description
"Base identity for identifying the line paths on an
automatic protection switch";
}
identity PRIMARY {
base APS_PATHS;
description
"The primary line path connected to an automatic protection
switch port indicating the primary/preferred path";
}
identity SECONDARY {
base APS_PATHS;
description
"The secondary line path connected to an automatic protection
switch port indicating the secondary path";
}
// grouping statements
grouping aps-input-port-config {
description
"Grouping for config related to unidirectional automatic
protection switch input ports";
leaf enabled {
type boolean;
default "true";
description
"This leaf contains the configured, desired state of the
port. Disabling the port turns off alarm reporting for
the port";
}
leaf target-attenuation {
type decimal64 {
fraction-digits 2;
}
units dB;
description
"Target attenuation of the variable optical attenuator
associated with the port in increments of 0.01 dB.";
}
}
grouping aps-output-port-config {
description
"Grouping for config related to unidirectional automatic
protection switch output ports";
leaf target-attenuation {
type decimal64 {
fraction-digits 2;
}
units dB;
description
"Target attenuation of the variable optical attenuator
associated with the port in increments of 0.01 dB";
}
}
grouping aps-input-port-state {
description
"Grouping for state related to unidirectional automatic
protection switch input ports";
leaf attenuation {
type decimal64 {
fraction-digits 2;
}
units dB;
description
"The attenuation of the variable optical attenuator
associated with the port in increments of 0.01 dB.";
}
container optical-power {
description
"The optical input power of this port in units of
0.01dBm. Optical input power represents the signal
traversing from an external destination into the module.
The power is measured before any attenuation. If avg/min/max
statistics are not supported, the target is expected to
just supply the instant value";
uses oc-types:avg-min-max-instant-stats-precision2-dBm;
}
}
grouping aps-output-port-state {
description
"Grouping for state related to unidirectional automatic
protection switch output ports";
leaf attenuation {
type decimal64 {
fraction-digits 2;
}
units dB;
description
"The attenuation of the variable optical attenuator
associated with the port in increments of 0.01 dB";
}
container optical-power {
description
"The optical output power of this port in units of
0.01dBm. Optical output power represents the signal
traversing from the module to an external destination. The
power is measured after any attenuation. If avg/min/max
statistics are not supported, the target is expected to
just supply the instant value";
uses oc-types:avg-min-max-instant-stats-precision2-dBm;
}
}
grouping aps-ports {
description
"Top level grouping for automatic protection switch ports";
container line-primary-in {
description
"Container for information related to the line primary
input port";
container config {
description
"Configuration data for the line primary input port";
uses aps-input-port-config;
}
container state {
config false;
description
"State data for the line primary input port";
uses aps-input-port-config;
uses aps-input-port-state;
}
}
container line-primary-out {
description
"Container for information related to the line primary
output port";
container config {
description
"Configuration data for the line primary output port";
uses aps-output-port-config;
}
container state {
config false;
description
"State data for the line primary output port";
uses aps-output-port-config;
uses aps-output-port-state;
}
}
container line-secondary-in {
description
"Container for information related to the line secondary
input port";
container config {
description
"Configuration data for the line secondary input port";
uses aps-input-port-config;
}
container state {
config false;
description
"State data for the line secondary input port";
uses aps-input-port-config;
uses aps-input-port-state;
}
}
container line-secondary-out {
description
"Container for information related to the line secondary
output port";
container config {
description
"Configuration data for the line secondary output port";
uses aps-output-port-config;
}
container state {
config false;
description
"State data for the line secondary output port";
uses aps-output-port-config;
uses aps-output-port-state;
}
}
container common-in {
description
"Container for information related to the line common
input port";
container config {
description
"Configuration data for the line common input port";
uses aps-input-port-config;
}
container state {
config false;
description
"State data for the line common input port";
uses aps-input-port-config;
uses aps-input-port-state;
}
}
container common-output {
description
"Container for information related to the line common
output port";
container config {
description
"Configuration data for the line common output port";
uses aps-output-port-config;
}
container state {
config false;
description
"State data for the line common output port";
uses aps-output-port-config;
uses aps-output-port-state;
}
}
}
grouping aps-config {
description
"Configuration data for automatic protection switch modules";
leaf name {
type leafref {
path "/oc-platform:components/oc-platform:component/" +
"oc-platform:name";
}
description
"Reference to the component name (in the platform model)
corresponding to this automatic protection switch module
in the device";
}
leaf revertive {
type boolean;
description
"Revertive behavior of the module.
If True, then automatically revert after protection switch
once the fault is restored.";
}
leaf primary-switch-threshold {
type decimal64 {
fraction-digits 2;
}
units dBm;
description
"The threshold at which the primary line port will switch to
the opposite line port in increments of 0.01 dBm. If the
hardware supports only one switch threshold for primary and
and secondary ports then it is recommended to set both
primary-switch-threshold and secondary-switch-threshold to
the same value to be explicit";
}
leaf primary-switch-hysteresis {
type decimal64 {
fraction-digits 2;
}
units dB;
description
"The delta in 0.01 dB between the primary-switch-threshold
and the signal received before initiating a reversion in
order to prevent toggling between ports when an input
signal is very close to threshold. If the hardware supports
only one switch hysteresis for primary and secondary ports
then it is recommended to set both primary-switch-threshold
and secondary-switch-threshold to the same value to be
explicit";
}
leaf secondary-switch-threshold {
type decimal64 {
fraction-digits 2;
}
units dBm;
description
"The threshold at which the secondary line port will switch to
the opposite line port in increments of 0.01 dBm. If the
hardware supports only one switch threshold for primary and
and secondary ports then it is recommended to set both
primary-switch-threshold and secondary-switch-threshold to
the same value to be explicit";
}
leaf secondary-switch-hysteresis {
type decimal64 {
fraction-digits 2;
}
units dB;
description
"The delta in 0.01 dB between the secondary-switch-threshold
and the signal received before initiating a reversion in
order to prevent toggling between ports when an input
signal is very close to threshold. If the hardware supports
only one switch hysteresis for primary and secondary ports
then it is recommended to set both primary-switch-threshold
and secondary-switch-threshold to the same value to be
explicit";
}
}
grouping aps-state {
description
"State data for automatic protection switch modules";
leaf active-path {
type identityref {
base APS_PATHS;
}
description
"Indicates which line path on the automatic protection switch
is currently the active path connected to the common port";
}
}
grouping automatic-protection-switch-top {
description
"Top level grouping for automatic protection switch data";
container aps-modules {
description
"Enclosing container for list of automatic protection
switch modules";
list aps-module {
key "name";
description
"List of automatic protection switch modules present
in the device";
leaf name {
type leafref {
path "../config/name";
}
description
"Reference to the config name list key";
}
container config {
description
"Configuration data for an automatic protection
switch module";
uses aps-config;
}
container state {
config false;
description
"Operational state data for an automatic protection
switch module";
uses aps-config;
uses aps-state;
}
container ports {
description
"Top level grouping for automatic protection switch ports";
uses aps-ports;
}
}
}
}
grouping transport-line-protection-top {
description
"Top level grouping for transport line protection data";
container aps {
description
"Top level grouping for automatic protection switch data";
uses automatic-protection-switch-top;
}
}
// data definition statements
uses transport-line-protection-top;
}