| * Copyright 2017-present Open Networking Foundation |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| package org.onosproject.incubator.net.l2monitoring.soam; |
| |
| import java.time.Duration; |
| |
| import org.onosproject.incubator.net.l2monitoring.cfm.identifier.MepId; |
| import org.onosproject.incubator.net.l2monitoring.cfm.Mep; |
| import org.onosproject.incubator.net.l2monitoring.soam.delay.DelayMeasurementCreate; |
| |
| /** |
| * A base interface with attributes that are common to both Delay and Loss Measurements. |
| */ |
| public interface MeasurementCreateBase { |
| /** |
| * The version of the PDUs used to perform Loss or Delay Measurement. |
| * The exact PDUs to use are specified by this object in combination with measurement-type |
| * @return The version of the PDUs |
| */ |
| DelayMeasurementCreate.Version version(); |
| |
| /** |
| * The remote MEP to perform the tests against. |
| * @return An ID of a MEP |
| */ |
| MepId remoteMepId(); |
| |
| /** |
| * The interval between Loss or Delay Measurement OAM message transmission. |
| * For Loss Measurement monitoring applications the default value is 1 sec. |
| * This object is not applicable if measurement-type is set to 'ccm' and is ignored for that Loss Measurement Type |
| * @return A java Duration |
| */ |
| Duration messagePeriod(); |
| |
| /** |
| * The priority of frames with Performance Monitoring OAM message information. |
| * @return A priority enumerated value 0-7 |
| */ |
| Mep.Priority priority(); |
| |
| /** |
| * The Loss Measurement frame size between 64 bytes and the maximum transmission unit of the EVC. |
| * The range of frame sizes from 64 through 2000 octets need to be supported, |
| * and the range of frame sizes from 2001 through 9600 octets is suggested be supported. |
| * The adjustment to the frame size of the standard frame size is accomplished |
| * by the addition of a Data or Test TLV. A Data or Test TLV is only added to |
| * the frame if the frame size is greater than 64 bytes |
| * @return frame size in bytes |
| */ |
| Short frameSize(); |
| |
| /** |
| * The LM data pattern included in a Data TLV. |
| * when the size of the LM frame is determined by the frame-size object and test-tlv-included is 'false'. |
| * If the frame size object does not define the LM frame size or |
| * test-tlv-included is 'true' the value of this object is ignored |
| * @return The data pattern - ones or zeroes |
| */ |
| DelayMeasurementCreate.DataPattern dataPattern(); |
| |
| /** |
| * Whether a Test TLV or Data TLV is included when the size of the LM frame is determined by the frame-size object. |
| * If the frame-size object does not define the LM frame size the value of |
| * this object is ignored. |
| * @return true indicates that the Test TLV is to be included, false indicates it is not |
| */ |
| boolean testTlvIncluded(); |
| |
| /** |
| * The type of test pattern to be sent in the LM frame Test TLV. |
| * when the size of LM PDU is determined by the frame-size object and |
| * test-tlv-included is 'true'. |
| * If the frame size object does not define the LM frame size or |
| * test-tlv-included is 'false' the value of this object is ignored |
| * @return A TLV pattern enum |
| */ |
| DelayMeasurementCreate.TestTlvPattern testTlvPattern(); |
| |
| /** |
| * The Measurement Interval for FLR statistics. |
| * A Measurement Interval of 15 minutes needs to be supported, other |
| * intervals may be supported. |
| * @return A java Duration |
| */ |
| Duration measurementInterval(); |
| |
| /** |
| * The number of completed measurement intervals to store in the history statistic table. |
| * At least 32 completed measurement intervals are to be stored. |
| * 96 measurement intervals are recommended to be stored |
| * @return The number to be stored. |
| */ |
| Short numberIntervalsStored(); |
| |
| /** |
| * Whether the measurement intervals for the Loss Measurement session are aligned with a zero offset to real time. |
| * The value 'true' indicates that each Measurement Interval starts at a time |
| * which is aligned to NE time source hour if the interval is a factor of an |
| * hour, i.e. 60min/15min = 4. For instance, a measurement time interval of |
| * 15 minutes would stop/start the measurement interval at 0, 15, 30, and 45 |
| * minutes of an hour. A measurement interval of 7 minutes would not align to |
| * the hour since 7 minutes is NOT a factor of an hour, i.e. 60min/7min = 8.6, |
| * and the behavior is the same as if the object is set to 'false'. |
| * The value 'false' indicates that each Measurement Interval starts at a time |
| * which is indicated by repetition-period. |
| * One side effect of the usage of this parameter is that if the value is true |
| * and the repetition-period is not a factor of an hour then the start of the |
| * next Measurement Interval will be delayed until the next factor of an hour. |
| * @return See above for the meaning of true and false |
| */ |
| boolean alignMeasurementIntervals(); |
| |
| /** |
| * The offset in minutes from the time of day value. |
| * if align-measurement-intervals is 'true' and the repetition time is a factor |
| * of 60 minutes. If not, the value of this object is ignored. |
| * If the Measurement Interval is 15 minutes and align-measurement-intervals |
| * is true and if this object was set to 5 minutes, the Measurement Intervals |
| * would start at 5, 20, 35, 50 minutes past each hour |
| * @return A java Duration |
| */ |
| Duration alignMeasurementOffset(); |
| |
| /** |
| * Defines the session start time. |
| * @return An object with the start time type and optionally an instant |
| */ |
| StartTime startTime(); |
| |
| /** |
| * Defines the session stop time. |
| * @return An object with the stop time type and optionally an instant |
| */ |
| StopTime stopTime(); |
| |
| /** |
| * Indicates whether the current session is defined to be 'proactive' or 'on-demand. |
| * @return An enumerated value |
| */ |
| SessionType sessionType(); |
| |
| /** |
| * Builder for {@link MeasurementCreateBase}. |
| */ |
| public interface MeasCreateBaseBuilder { |
| MeasCreateBaseBuilder messagePeriod( |
| Duration messagePeriod) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder frameSize(Short frameSize) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder dataPattern(DelayMeasurementCreate.DataPattern dataPattern); |
| |
| MeasCreateBaseBuilder testTlvIncluded(boolean testTlvIncluded); |
| |
| MeasCreateBaseBuilder testTlvPattern(DelayMeasurementCreate.TestTlvPattern testTlvPattern); |
| |
| MeasCreateBaseBuilder measurementInterval( |
| Duration measurementInterval) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder numberIntervalsStored( |
| Short numberIntervalsStored) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder alignMeasurementIntervals( |
| boolean alignMeasurementIntervals); |
| |
| MeasCreateBaseBuilder alignMeasurementOffset( |
| Duration alignMeasurementOffset) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder startTime(StartTime startTime) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder stopTime(StopTime stopTime) throws SoamConfigException; |
| |
| MeasCreateBaseBuilder sessionType(SessionType sessionType); |
| |
| } |
| |
| /** |
| * Supported session types. |
| * reference [MEF SOAM IA] R3 |
| */ |
| public enum SessionType { |
| /** |
| * The current session is 'proactive'. |
| */ |
| PROACTIVE, |
| /** |
| * The current session is 'on-demand'. |
| */ |
| ONDEMAND; |
| } |
| |
| } |