[ONOS-5598] Alarm Consumer for Fujitsu OLT

Change-Id: I3206307f6adcc078d9b0a1aa26d6de6ad00f9824
diff --git a/drivers/fujitsu/BUCK b/drivers/fujitsu/BUCK
index 2eeaa33..1dc97a9 100644
--- a/drivers/fujitsu/BUCK
+++ b/drivers/fujitsu/BUCK
@@ -6,6 +6,7 @@
     '//lib:org.apache.karaf.shell.console',
     '//cli:onos-cli',
     '//apps/optical-model:onos-apps-optical-model',
+    '//incubator/api:onos-incubator-api',
 ]
 
 TEST_DEPS = [
diff --git a/drivers/fujitsu/src/main/java/org/onosproject/drivers/fujitsu/FujitsuVoltAlarmConsumer.java b/drivers/fujitsu/src/main/java/org/onosproject/drivers/fujitsu/FujitsuVoltAlarmConsumer.java
new file mode 100644
index 0000000..9d56355
--- /dev/null
+++ b/drivers/fujitsu/src/main/java/org/onosproject/drivers/fujitsu/FujitsuVoltAlarmConsumer.java
@@ -0,0 +1,297 @@
+/*
+ * Copyright 2016-present Open Networking Laboratory
+ *
+ * Licensed under the Apache License, Version 2.0 (the "License");
+ * you may not use this file except in compliance with the License.
+ * You may obtain a copy of the License at
+ *
+ *     http://www.apache.org/licenses/LICENSE-2.0
+ *
+ * Unless required by applicable law or agreed to in writing, software
+ * distributed under the License is distributed on an "AS IS" BASIS,
+ * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+ * See the License for the specific language governing permissions and
+ * limitations under the License.
+ */
+
+package org.onosproject.drivers.fujitsu;
+
+import com.google.common.collect.ImmutableList;
+import org.apache.commons.configuration.HierarchicalConfiguration;
+import org.onosproject.drivers.utilities.XmlConfigParser;
+import org.onosproject.incubator.net.faultmanagement.alarm.Alarm;
+import org.onosproject.incubator.net.faultmanagement.alarm.AlarmConsumer;
+import org.onosproject.incubator.net.faultmanagement.alarm.AlarmEntityId;
+import org.onosproject.incubator.net.faultmanagement.alarm.DefaultAlarm;
+import org.onosproject.net.DeviceId;
+import org.onosproject.net.driver.AbstractHandlerBehaviour;
+import org.onosproject.net.driver.DriverHandler;
+import org.onosproject.netconf.NetconfController;
+import org.onosproject.mastership.MastershipService;
+
+import org.slf4j.Logger;
+
+import java.io.IOException;
+import java.util.ArrayList;
+import java.util.List;
+import java.text.SimpleDateFormat;
+import java.text.ParseException;
+import java.util.Date;
+import java.util.TimeZone;
+
+import java.nio.charset.StandardCharsets;
+import java.io.ByteArrayInputStream;
+
+import static org.onosproject.incubator.net.faultmanagement.alarm.Alarm.SeverityLevel;
+import static com.google.common.base.Preconditions.checkNotNull;
+import static org.onosproject.drivers.fujitsu.FujitsuVoltXmlUtility.*;
+import static org.slf4j.LoggerFactory.getLogger;
+
+/**
+ * Fujitsu vOLT specific implementation to provide a list of current alarms.
+ */
+public class FujitsuVoltAlarmConsumer extends AbstractHandlerBehaviour implements AlarmConsumer {
+    private final Logger log = getLogger(getClass());
+    private final SimpleDateFormat dateFormat = new SimpleDateFormat("yyyy-MM-dd HH:mm:ss");
+
+    private static final TimeZone ZONE =  TimeZone.getTimeZone("UTC");
+
+    private static final String VOLT_ALERTS = "volt-alerts";
+    private static final String OLT_ACTIVE_ALERTS = "olt-active-alerts";
+    private static final String ALERT_INFO = "alert-info";
+    private static final String ALERT_SEQNUM = "alert-seqnum";
+    private static final String ALERT_TYPE = "alert-type";
+    private static final String ALERT_TIME = "alert-time";
+    private static final String ALERT_CLEAR = "alert-clear";
+    private static final String RESOURCE_ID = "resource-id";
+    private static final String SEVERITY = "severity";
+    private static final String IP_ADDRESS = "ip-address";
+    private static final String DATE = "date";
+    private static final String TIME = "time";
+    private static final String OLT_ACTIVE_ALERTS_KEY =
+            "data." + VOLT_NE + ".volt-alerts.olt-active-alerts";
+    private static final String SLASH = "/";
+    private DeviceId ncDeviceId;
+
+    private enum AlertResourceType {
+        UNKNOWN,
+        PONLINK,
+        ONU,
+        SYSTEM
+    }
+
+    private enum AlertSeverity {
+        INFO("info", SeverityLevel.WARNING),
+        MINOR("minor", SeverityLevel.MINOR),
+        MAJOR("major", SeverityLevel.MAJOR),
+        CRITICAL("critical", SeverityLevel.CRITICAL);
+
+        private String text;
+        private SeverityLevel level;
+
+        AlertSeverity(String text, SeverityLevel level) {
+            this.text = text;
+            this.level = level;
+        }
+
+        public static SeverityLevel convertToAlarmSeverityLevel(String text) {
+            for (AlertSeverity severity : AlertSeverity.values()) {
+                if (text.equalsIgnoreCase(severity.text)) {
+                    return severity.level;
+                }
+            }
+            return SeverityLevel.INDETERMINATE;
+        }
+    }
+
+    @Override
+    public List<Alarm> consumeAlarms() {
+        DriverHandler handler = handler();
+        NetconfController controller = handler.get(NetconfController.class);
+        MastershipService mastershipService = handler.get(MastershipService.class);
+        ncDeviceId = handler.data().deviceId();
+        checkNotNull(controller, "Netconf controller is null");
+
+        if (!mastershipService.isLocalMaster(ncDeviceId)) {
+            log.warn("Not master for {} Use {} to execute command",
+                     ncDeviceId,
+                     mastershipService.getMasterFor(ncDeviceId));
+            return null;
+        }
+
+        dateFormat.setTimeZone(ZONE);
+        List<Alarm> alarms = new ArrayList<>();
+        try {
+            StringBuilder request = new StringBuilder();
+            request.append(VOLT_NE_OPEN + VOLT_NE_NAMESPACE)
+                .append(ANGLE_RIGHT + NEW_LINE)
+                .append(buildStartTag(VOLT_ALERTS))
+                .append(buildEmptyTag(OLT_ACTIVE_ALERTS))
+                .append(buildEndTag(VOLT_ALERTS))
+                .append(VOLT_NE_CLOSE);
+
+            String reply = controller.getDevicesMap()
+                               .get(ncDeviceId)
+                               .getSession()
+                               .get(request.toString(), null);
+            if (reply != null) {
+                alarms = parseVoltActiveAlerts(XmlConfigParser.
+                    loadXml(new ByteArrayInputStream(reply.getBytes(StandardCharsets.UTF_8))));
+            }
+        } catch (IOException e) {
+            log.error("Error reading alarms for device {} exception {}", ncDeviceId, e);
+        }
+
+        return ImmutableList.copyOf(alarms);
+    }
+
+    /**
+     * Parses XML string to get controller information.
+     *
+     * @param cfg a hierarchical configuration
+     * @return a list of alarms
+     */
+    private List<Alarm> parseVoltActiveAlerts(HierarchicalConfiguration cfg) {
+        List<Alarm> alarms = new ArrayList<>();
+        List<HierarchicalConfiguration> fields =
+                cfg.configurationsAt(OLT_ACTIVE_ALERTS_KEY);
+
+        for (HierarchicalConfiguration sub : fields) {
+            List<HierarchicalConfiguration> childFields =
+                    sub.configurationsAt(ALERT_INFO);
+
+            for (HierarchicalConfiguration child : childFields) {
+                try {
+                    int seqNum = Integer.parseInt(child.getString(ALERT_SEQNUM));
+                    boolean cleared = Boolean.parseBoolean(child.getString(ALERT_CLEAR));
+                    String alertType = child.getString(ALERT_TYPE);
+                    String severity = child.getString(SEVERITY);
+
+                    List<HierarchicalConfiguration> idFields =
+                            child.configurationsAt(RESOURCE_ID);
+                    if (idFields.isEmpty()) {
+                        log.error("{} does not exsit: SQ={}, TYPE={}, SEV={}, CLEARED={}",
+                                RESOURCE_ID, seqNum, alertType, severity, cleared);
+                        continue;
+                    }
+                    String alarmSrc = formAlarmSource(idFields);
+                    if (alarmSrc == null) {
+                        log.error("Cannot build description: SQ={}, TYPE={}, SEV={}, CLEARED={}",
+                                seqNum, alertType, severity, cleared);
+                        continue;
+                    }
+                    long timeRaised = getTimeRaised(child);
+                    log.debug("VOLT: ACTIVE ALERT: SQ={}, TYPE={}, SEV={}, CLEARED={}, TIME={}",
+                            seqNum, alertType, severity, cleared, timeRaised);
+
+                    SeverityLevel alarmLevel =
+                            AlertSeverity.convertToAlarmSeverityLevel(severity);
+                    if (alarmLevel.equals(SeverityLevel.INDETERMINATE)) {
+                        log.warn("Unknown severity: {}", severity);
+                    }
+                    DefaultAlarm.Builder alarmBuilder = new DefaultAlarm.Builder(
+                            ncDeviceId, alertType.toUpperCase(), alarmLevel, timeRaised)
+                            .forSource(AlarmEntityId.alarmEntityId(alarmSrc));
+                    alarms.add(alarmBuilder.build());
+                } catch (NumberFormatException e) {
+                    log.error("Non-number exception {}", e);
+                } catch (Exception e) {
+                    log.error("Exception {}", e);
+                }
+            }
+        }
+        return alarms;
+    }
+
+    /**
+     * Builds alarm source with resource information.
+     * @param idFields a hierarchical configuration
+     * @return formed alarm description
+     */
+    private String formAlarmSource(List<HierarchicalConfiguration> idFields) {
+        AlertResourceType resourceType = AlertResourceType.UNKNOWN;
+        StringBuilder alarmSrc = new StringBuilder();
+        String ipAddr = null;
+        int pon = ZERO;
+        int onu = ZERO;
+
+        for (HierarchicalConfiguration id : idFields) {
+            String value;
+            try {
+                value = id.getString(PONLINK_ID);
+                if (value == null) {
+                    resourceType = AlertResourceType.SYSTEM;
+                    ipAddr = id.getString(IP_ADDRESS);
+                } else {
+                    pon = Integer.parseInt(value);
+                    value = id.getString(ONU_ID);
+                    if (value == null) {
+                        resourceType = AlertResourceType.PONLINK;
+                    } else {
+                        resourceType = AlertResourceType.ONU;
+                        onu = Integer.parseInt(value);
+                    }
+                }
+            } catch (NumberFormatException e) {
+                log.error("Non-number resource-id exception {}", e);
+                return null;
+            }
+        }
+
+        alarmSrc.append("other:");
+        alarmSrc.append(resourceType.name()).append(SLASH);
+        switch (resourceType) {
+            case PONLINK:
+                alarmSrc.append(pon);
+                break;
+            case ONU:
+                alarmSrc.append(pon).append(HYPHEN).append(onu);
+                break;
+            case SYSTEM:
+                if (ipAddr != null) {
+                    alarmSrc.append(ipAddr);
+                }
+                break;
+            default:
+                break;
+        }
+        return alarmSrc.toString();
+    }
+
+    /**
+     * Converts time and date information from device.
+     * @param cfg a hierarchical configuration
+     * @return converted time from device or system time
+     */
+    private long getTimeRaised(HierarchicalConfiguration cfg) {
+        String strDate;
+        String strTime;
+        long timeRaised;
+
+        List<HierarchicalConfiguration> timeFields =
+                cfg.configurationsAt(ALERT_TIME);
+        if (timeFields.isEmpty()) {
+            log.debug("{} does not exsit", ALERT_TIME);
+        } else {
+            for (HierarchicalConfiguration child : timeFields) {
+                strDate = child.getString(DATE);
+                strTime = child.getString(TIME);
+                if ((strDate != null) && (strTime != null)) {
+                    try {
+                        Date date = dateFormat.parse(strDate + SPACE + strTime);
+                        timeRaised = date.getTime();
+                        log.debug("{} {} coverted to {}", strDate, strTime, timeRaised);
+                        return timeRaised;
+                    } catch (ParseException e) {
+                        log.error("Cannot parse exception {} {} {}", strDate, strTime, e);
+                    }
+                } else {
+                    log.error("{} or {} does not exsit", DATE, TIME);
+                }
+            }
+        }
+        // Use the system's time instead.
+        return System.currentTimeMillis();
+    }
+
+}
diff --git a/drivers/fujitsu/src/main/resources/fujitsu-drivers.xml b/drivers/fujitsu/src/main/resources/fujitsu-drivers.xml
index 7a0a237..b0dbed6 100644
--- a/drivers/fujitsu/src/main/resources/fujitsu-drivers.xml
+++ b/drivers/fujitsu/src/main/resources/fujitsu-drivers.xml
@@ -36,5 +36,7 @@
                    impl="org.onosproject.drivers.fujitsu.FujitsuVoltFwdlConfig"/>
         <behaviour api="org.onosproject.drivers.fujitsu.behaviour.VoltNeConfig"
                    impl="org.onosproject.drivers.fujitsu.FujitsuVoltNeConfig"/>
+        <behaviour api="org.onosproject.incubator.net.faultmanagement.alarm.AlarmConsumer"
+                   impl="org.onosproject.drivers.fujitsu.FujitsuVoltAlarmConsumer"/>
     </driver>
 </drivers>