CORD-389 Fix for Accton 6712 deployment
Related to this topic:
- Disable the meter collector since right now it is not supported
- Implement extension VLAN ID selector/treatment for OFDPA
Since it requires two special flow entries to match untagged packets
0x1ffe/no mask (filtering rule, need to go first)
0x0000/0x1fff setvid 0x0ffe (assignment rule, need to go second)
- Not able to point /32 IP address to ECMP group. Use /31 instead.
In addition:
- Implement serializer for ExtensionCriterion
Change-Id: I621b3ad14014d7e6945c014cdae4f7cd2939288e
diff --git a/providers/openflow/flow/src/main/java/org/onosproject/provider/of/flow/impl/OpenFlowRuleProvider.java b/providers/openflow/flow/src/main/java/org/onosproject/provider/of/flow/impl/OpenFlowRuleProvider.java
index 6469cda..b8899df 100644
--- a/providers/openflow/flow/src/main/java/org/onosproject/provider/of/flow/impl/OpenFlowRuleProvider.java
+++ b/providers/openflow/flow/src/main/java/org/onosproject/provider/of/flow/impl/OpenFlowRuleProvider.java
@@ -219,7 +219,8 @@
private void createCollector(OpenFlowSwitch sw) {
if (adaptiveFlowSampling) {
// NewAdaptiveFlowStatsCollector Constructor
- NewAdaptiveFlowStatsCollector fsc = new NewAdaptiveFlowStatsCollector(sw, flowPollFrequency);
+ NewAdaptiveFlowStatsCollector fsc =
+ new NewAdaptiveFlowStatsCollector(driverService, sw, flowPollFrequency);
fsc.start();
afsCollectors.put(new Dpid(sw.getId()), fsc);
} else {